I started in 2017 with a 1 kW inverter and four used panels plugged into a wall socket. Then came lead-acid (a mistake), more inverters, a DIY mounting frame drilled through the roof membrane and a home-built battery. Today I have ~13.9 kWp, a Deye 10 kW inverter and 34 kWh of LiFePO4. The main lesson? Compromise solutions are the most expensive ones – but starting small still beats not starting at all.

A colleague got me into solar in 2017. He showed me that you don't need much to make it work: a grid-tie inverter, a few panels and a wall socket. Since then I have rebuilt my system more times than I'd like to admit. Here is the whole journey – mistakes included.

What I have today is summed up in My solar setup. This article is about how I got there.

Timeline

WhenWhat was added
2017Sun 1 kW grid-tie inverter, 4 used 250 W panels, official grid connection (1 kW export limit)
thenLead-acid battery 2 × 160 Ah with an MPPT charge controller – gone after six months
thenSecond Sun 2 kW inverter and stronger used panels, export still max. 1 kW
~2021Panels on the house roof, DIY frame from L-profiles, GoodWe 5 kW hybrid, U/f guard, first LiFePO4 105 Ah
2024Deye 10 kW inverter, more panels, 10 kW export limit, 280 Ah battery
2024Second 280 Ah battery in a case → 34 kWh in total. In April, frameless DAH panels on the carport
spring 2026Everything from scratch: K2 mounting system, 22 × JA Solar 500 W, repaired roof

2017: an inverter in a wall socket

The first one was a small Sun 1 kW grid-tie inverter. Back then it cost €400. I paired it with 4 used 250 W panels – huge ones, €100 each. That's all you need to start: the panels produce DC, the inverter turns it into AC and feeds it into the house wiring.

My first used 250 W panel, the Sun inverter with its display and the Epever MPPT controller from the lead-acid days

The tech was simple, the paperwork wasn't. Making it legal meant design documentation, certificates, declarations, an inspection report and a pile of other things. All by e-mail, and it took about 4 months. But it worked out – I was officially connected with a 1 kW export limit. By the way, I still have that inverter on a shelf at home.

Lead-acid: a step sideways

I immediately wanted to store energy for later too. LiFePO4 was unknown and expensive to me back then, so I went for lead-acid – 2 × 160 Ah. Charging was handled by an Epever Tracer MPPT controller and the inverter drew power straight from the battery. The Sun inverter had a 22–65 V input, so a 24 V setup was enough to start with.

After six months I found out I could reasonably use only half of the capacity. So I got rid of it and started shifting consumption to the hours of production instead – running appliances while the sun shines.

A second inverter and solar fever

Seeing it work got me so excited that I soon added another Sun 2 kW inverter and stronger panels – second-hand again. Export stayed limited to 1 kW.

The fever kept rising and the unused house roof kept me awake at night. Until then, everything was on the carport only. More panels came, a DIY frame from L-profiles, holes in the roof and a pile of quick makeshift solutions. I thought I'd save money – original flat-roof mounting systems cost more than the panels.

Plus a GoodWe GW5048-EM hybrid inverter from a classifieds site, in parallel with the original Sun. Used OMSUN 260 W panels were added as well.

GoodWe 5 kW hybrid with the Sun on the wall and the distribution box with the U/f guard; on the right a Gobel LiFePO4 cell (EVE LF280K)

Since I want everything done properly, I went through the whole process with the grid operator again. With two inverters I also had to install a U/f guard – a protection relay that disconnects the sources when grid voltage or frequency is off. It wasn't cheap, but above all it was impossible to find anywhere.

My first LiFePO4 battery

Along the way I built my first LiFePO4 battery: 105 Ah cells and a JK BMS 200 A. I learned as I went – compression or not, which cables, which fuses. And above all, how to set up the inverter and the BMS so they talk to each other. It worked. This DIY pack still runs today.

A steep tilt and restless nights

For the frame I went for the optimal tilt to get the most out of the panels – especially outside summer. That meant a steep angle and a large surface catching the wind. It survived on the roof for a while, but I didn't sleep well. So I climbed back up and lowered the tilt so the panels wouldn't act like a sail.

The old DIY frame with a lower tilt on the flat roof

Deye and the 10 kW ceiling

In 2024 the roof still wasn't full, panel prices were falling like autumn leaves, and a Deye inverter arrived on the market that met all my needs. Another round: new inverter, more panels, a bigger frame and new paperwork. This time online and fast. The result: a 10 kW export limit – the ceiling I can feed into the grid as a private person.

The inverter got 280 Ah cells from Gobel Power, ordered directly from China. I assembled them on a shelf with a BMS. Over time it started to bother me – the battery wasn't compressed and the cells began to swell slightly (no, they weren't overcharged).

Batteries on the shelf next to the Deye – no case, no compression

So I decided the next battery would be done properly: more 280 Ah cells, two cases with a proper BMS and fusing. The first 280 Ah cells moved into a case too. Only the 105 Ah pack stayed outside. Today that's my ~34 kWh.

280 Ah cells assembled before moving into a case, and today's state – Deye, two Gobel cases and the 105 Ah pack in a box

The system was fully working again, I just struggled with the communication and accuracy of the JK BMS. That's a chapter of its own – I wrote it up in Accurate SOC in a Deye inverter.

2024: new panels on the carport

In April 2024 I replaced the old panels on the carport with 6 frameless DAH panels (~480 Wp). The camera recorded it – the swap took just under an hour and a half.

The carport before and after: old panels and the frameless DAH ones

Once and properly

The roof was almost full and the total was only about 8.5 kWp. On top of that I still wasn't happy with the homemade frame drilled through the roof membrane into the beams. Yes, you read that right – I turned my roof into a sieve. Nothing ever leaked, but I wasn't at peace with it. And the electric car pushed up demand for energy.

So came – from today's point of view – the final decision: let's do it once and do it properly. A proper frame, proper panels that use as much of the area as possible, built to last "forever".

After a month of planning and research: K2 flat-roof mounting system, JA Solar 500 W panels and above all a plan for patching the roof. I learned to weld Fatrafol PVC membrane and in spring 2026 off we went. Panels down, old frame removed, roof cleaned, holes repaired and the new setup installed.

Removal: the old frames without panels
Installation: K2 rails and new JA Solar panels ready on the roof
Done: 22 JA Solar 500 W panels on the K2 system

Today the roof holds 22 × JA Solar 500 W and the carport 6 × DAH – about 13.9 kWp in total. The system runs flawlessly. Not that a few more panels wouldn't earn their keep…

What it cost

I probably have the most expensive solar system in the neighbourhood if I count all the previous rounds – and I'd rather not know. The current setup:

PartPrice
Deye 10 kW inverter€1,700
Panels (incl. shipping)€1,700
Battery ~34 kWh€3,500
K2 mounting system~€1,000
Cables and the rest~€300 (estimate)
Total~€8,000
Labourpriceless 🙂

What I learned

  1. It is highly addictive. Making your own energy and being at least a bit independent of the grid – once it gets you, it won't let go.
  2. Do things properly the first time, even if it looks more expensive. Trust me, compromise solutions are the most expensive ones.
  3. Go for the maximum your roof and grid operator allow, even if you don't seem to need it today. The demand will come – an electric car, water heating, cooling…
  4. But despite points 1–3, starting small is better than not starting at all. 🙂